Japanese Website »

Water Message : presented by UP., Corporation.

Hydrogen Gas Inhaler MHG-4280

Night Mode: Fitted with main unit lamp off mode for 10h run time.

Hydrogen Gas Inhaler MHG-4280

 

Hydrogen gas adjusted to around 6.5% can be inhaled with approximately 4,000 cc of air per minute.

Features of Hydrogen Gas Inhaler MHG-4280

panel

Real-time display of hydrogen gas density to be inhaled

The hydrogen gas inhaler MHG-4280 measures and displays the hydrogen gas density of the inhaled air mixture in real time using a system that constantly monitors the hydrogen gas generation status and dilution air flow rate.


The hydrogen gas density to be inhaled is constantly controlled and safe.

The hydrogen gas inhaler MHG-4280 controls the hydrogen density to below the explosion limit in all processes from hydrogen generation to inhalation. MHG-4280 makes it possible by blowing dilution air on the electrode surface where hydrogen gas is generated through electrolytic decomposition of water.


up_down

Generation time and settings

Pressing the button " UP" or " DOWN" increases or decreases the generation time display by 5 minutes, and the time can be set. The time setting range is from 5 to 90 minutes.


start_stop

Start and stop switch of inhalation

Pressing this button while the machine is stopped starts operation and the green light comes on. A convenient pause function is provided.


Hydrogen gas concentration during continuous use

The method of manufacturing the hydrogen gas inhaler, the principle of supplying hydrogen gas, and the results of measuring the hydrogen density for 3 hours after startup with the hydrogen density setting of the hydrogen gas inhaler at approximately 3% were published in, an international scientific journal specializing in medical gases based in the United States. LINK: MEDICAL GAS RESEARCH

graph


" MHG-4280 " Detail

Model number MHG-4280 Specifications ambient temperature

approx. 10 - 40℃

Size W400 × H515 × D250 (mm) Rated current 2.5A
Weight approx. 16 kg (dry weight) Operating relative humidity approx. 0 to 85% RH
Purified water tank capacity approx. 550ml (when water is supplied to the MAX position) Water supply quality purified water, distilled water
Supply volume 4 L/min. Installation environment Indoor installation only
Hydrogen gas density 6.2 - 8.0% Continuous use time approx. 90 min
Hydrogen production approx. 280 ml/min. Safety device current fuse 4A
Purified water consumption approx. 60ml/h Accessories nasal cannula, purified water, cooling pot, drainage receptacle
Rated voltage, frequency AC100V 50/60Hz Consumables nasal cannula, purified water

Inquiry Form